WATER QUALITY:
GROUND WATER QUALITY STANDARD
TCVN 5944-1995
1.    Scope

1.1    This standard specifies parameter limits and maximum allowable concentrations of pollutants in ground water.

1.2    This standard is applied to evaluation of quality of a ground water source and to monitoring of pollution status of the ground water in a specific area.

2.    Limitation Values

2.1    Parameters, pollutants and limitation value of those in ground water are shown in the table 1.

2.2    Standard methods of analysis of parameters and concentrations of pollutants in ground water are specified in available current TCVNs.

Table 1
Parameter Limits and Maximum Allowable Concentrations of Pollutants in Ground Water
Parameter and Pollutant
Unit
Limitation Value
1 pH value  
6,5 - 8,5
2 Colour
Pt - Co
5 - 50
3 Hardness (as CaCO3)
mg/l
300 - 500
4 Total solids
mg/l
750 - 1500
5 Arsenic
mg/l
0,05
6 Cadmium
mg/l
0,01
7 Chloride
mg/l
200 - 600
8 Lead
mg/l
0,05
9 Chromium (VI)
mg/l
0,05
10 Cyanide
mg/l
0,01
11 Copper
mg/l
1,0
12 Fluoride
mg/l
1,0
13 Zink
mg/l
5,0
14 Manganese
mg/l
0,1 - 0,5
15 Nitrate
mg/l
45
16 Phenol compound
mg/l
0,001
17 Iron
mg/l
1 - 5
18 Sulphate
mg/l
200 ¸ 400
19 Mercury
mg/l
0,001
20 Selenium
mg/l
0,01
21 Fecal coli
MPN/100 ml
Not detectable
22 Coliform
MPN/100 ml
3